Brand: OMRON
Product model: K3HB-VLC-FLK3ET11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.84MB
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-VLC-FLK3ET11 Communications Manual.
Manual resetting and automatically resetting supported by one Relay K3HB-VLC-FLK3ET11
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Time specification: Instantaneous type K3HB-VLC-FLK3ET11 Communications Manual.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K3HB-VLC-FLK3ET11 Communications Manual.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltagees K3HB-VLC-FLK3ET11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-VLC-FLK3ET11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-L1ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-L1ET11 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-B1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK3ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK3ET11 AC100-240
Category: external supply 100mA DC5V type. I