K3HB-XAD-AT11 Communications Manual ()

Brand: OMRON
Product model: K3HB-XAD-AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-XAD-AT11 Communications Manual.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAD-AT11
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only 95mm superMeasuring current: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC K3HB-XAD-AT11 Communications Manual.
Supply voltage: 100-115 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed K3HB-XAD-AT11 Communications Manual.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phasee control, and cyclic control K3HB-XAD-AT11 Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XAD-AT11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Process Indicator
K3HB-X Series
OMRON Process Indicator K3HB-X Series
A Process Indicator Ideal for Discriminating
OMRON
Voltage and current panel meter
K3HB-XVA-L1AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-L1AT11 AC/DC24
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XVA-1 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-1 AC/DC24
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-L2AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-L2AT11 AC/DC24
Type of input: AC current input. Output type