OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-XVD-L1AT11 Communications Manual ()

K3HB-XVD-L1AT11 Communications Manual ()

Brand: OMRON
Product model: K3HB-XVD-L1AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; H, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XVD-L1AT11 Communications Manual K3HB-XVD-L1AT11
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard applicable certification (Power supply voltage: 100 to 240 VAC K3HB-XVD-L1AT11 Communications Manual.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-XVD-L1AT11 Communications Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltaages K3HB-XVD-L1AT11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-XVD-L1AT11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Voltage and current panel meter
K3HB-XVA-BCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-BCD1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC100-240
Type of input: AC current input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK1AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVD-FLK3AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK3AT11 AC100-240
Input type: DC voltage input type. Output ty