Input type: DC voltage input type.
Output type: DeviceNet; -; DeviceNet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XAD-AT11 User's Manual
K3HB-XAD-AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC K3HB-XAD-AT11 User's Manual.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit K3HB-XAD-AT11 User's Manual.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviceNetMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervolltages K3HB-XAD-AT11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-XAD-AT11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.