Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XVD-FLK1AT11 AC/DC24 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-XVD-FLK1AT11 AC/DC24
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVD-FLK1AT11 AC/DC24 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-XVD-FLK1AT11 AC/DC24 PDF datasheet.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputCategory: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XVD-FLK1AT11 AC/DC24 PDF catalog.
Action determine the coloor, can switch the green / Red 2 kinds of color display K3HB-XVD-FLK1AT11 AC/DC24 PDF catalog.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input