OMRON
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Voltage / current input >> K3HB-XVA-BCD1 AC100-240 Voltage and current panel meter

K3HB-XVA-BCD1 AC100-240 Voltage and current panel meter

OMRON K3HB-XVA-BCD1 AC100-240 Manual And Instructions
K3HB-XVA-BCD1 AC100-240 datasheetPDF datasheet

OMRON K3HB-XVA-BCD1 AC100-240 Product information and technical parameters:
Brand: OMRON
Name: Voltage and current panel meter
Model: K3HB-XVA-BCD1 AC100-240
Type of input: AC voltage input.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
D

Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000.0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits K3HB-XVA-BCD1 AC100-240.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 K3HB-XVA-BCD1 AC100-2400 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input K3HB-XVA-BCD1 AC100-240.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50kControl output: Contact output: Time-limit SPDT and,
switchable SPDT (time-limit - instantaneous) K3HB-XVA-BCD1 AC100-240.
Supply voltage: 110 VAC (50/60 Hz).
8-pin models.
Solid-state Timer with Valuable Multiple-time.
Ranges and Multiple-operating Modes.
Handles a wide range of applications through eight operating modes.
With H3BA-N8H models, the output type can be switched.
between time-limit DPDT and time-limit SPDT + instantaneous.
SPDT using a selector.
Setting rings (order separately) to enable consistent settings.
and to limit the setting range.
Panel Covers (order separately) to enable various panel.
designs.
CE marking.
UL, CSA and CCC certification, conforms to LR. Display type: UP display timer (increments form 0 to the set time).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC.
Rated time: 0.001 to 99.99 s.
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Seriees version cover a wide range of rated times; 9 K3HB-XVA-BCD1 AC100-240. 999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements K3HB-XVA-BCD1 AC100-240.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards.


...More relevant models >>>>