OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-XVD-L1AT11 User's Manual ()

K3HB-XVD-L1AT11 User's Manual ()

Brand: OMRON
Product model: K3HB-XVD-L1AT11
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; H, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XVD-L1AT11 User's Manual K3HB-XVD-L1AT11
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard applicable certification (Time specification: Instantaneous type K3HB-XVD-L1AT11 User's Manual.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XVD-L1AT11 User's Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-XVD-L1AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVD-L1AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Voltage and current panel meter
K3HB-XVA-L2AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-L2AT11 AC/DC24
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XVA-CPAC11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-CPAC11 AC/DC24
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-FLK3AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK3AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC21 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-CPAC21 AC/DC24
Input type: DC voltage input type. Output ty