OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-PPB-L1AT11 Communications Manual ()

K3HB-PPB-L1AT11 Communications Manual ()

Brand: OMRON
Product model: K3HB-PPB-L1AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.85MB
Input type: DC voltage/current.
Supply voltage: 24 VAC/VDC.
Comparative Output Model: None.
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, front-panel forced-zero, zero-limit functions K3HB-PPB-L1AT11 Communications Manual.
Easy confirmation of max/min display K3HB-PPB-L1AT11
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking. Input type: DC current input K3HB-PPB-L1AT11 Communications Manual.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-L1AT11 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeTime specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operatioon time,
is indicated from the start of operation K3HB-PPB-L1AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-PPB-L1AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Time interval table
K3HB-PPB-AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PPB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-L2AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XVA-L1AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-L1AT11 AC/DC24
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-L1AT11 AC100-240
Input type: DC voltage input type. Output ty