Brand: OMRON
Product model: K8AC-H11CC-FLK
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 7.32MB
Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AC-H11CC-FLK Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AC-H11CC-FLK
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AC-H11CC-FLK Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: DC voltage input type.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K8AC-H11CC-FLK Communications Manual.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemFunction: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1.
Three-phase Phase-sequence Phase-loss.
RRelay Using Voltage Detection Method K8AC-H11CC-FLK Manual.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operrating K8AC-H11CC-FLK Manual.
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.
Related products
OMRON
Digital Heater Element Burnout Detector
K8AC-H12CT-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H12CT-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H11PC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H11PC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H12PT-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H12PT-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H11CT-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H11CT-FLK
Power supply voltage: 100 to 240 VAC. Heater