Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Crimping.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XWT-OD08
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: 4PDT.
Time ranges: 0.04 s to 3 h.
Supply voltage: 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface mounting (with PCB terminals).
Miniature Timer Compatible with the MY Relay.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 7.5 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
XWT-OD08 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XWT-OD08&select=5