Sensing method: Convergent reflective.
Connection method: Pre-wired (2 m).
Sensing distance : 20 to 35 mm .
function Timer: With .
Model: NPN output.
Reliable Detection Unaffected by PCB.
Holes or Notches.
High-limit E3S-LS3@ is suitable for incorporation in devices.
Wide-range E3S-LS3@W is ideal for detecting tall components,
mounted on boards.
Timer function models available. Classification: Relay with Auxiliary Contact Block
CJ1W-AD081-V1
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 4PST-NO; Auxiliary Contact Block, DPST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. I/O Control UnitInsulation method: Photovoltage coupler.
Operation Display: Yes(green).
Output(SSR): DC.
Zero cross Function: --.
Rated output Load: 3 A(at 5 to 24 VDC).
Rated input voltage (socket): 48 VAC/VDC, 100 VAC, 110 VAC, 200 VAC, 230 VAC.
Applicable model: G3RV-SR700/500-A AC/DC48V,G3RV-SR700/500-A AC100V,
G3RV-SR700/500-A AC110V, G3RV-SR700/500-A AC200V, G3RV-SR700/500-A AC230V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
CJ1W-AD081-V1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=CJ1W-AD081-V1&select=5