Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 2.4 m3/min; 60 Hz, 2.7 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 2260 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
CP1W-32ET1
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. No. of poles: 5.
Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.18 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
L-shaped connectors (for DC).
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
CP1W-32ET1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=CP1W-32ET1&select=5