CJ1W-B7A04 B7A Interface Unit

OMRON CJ1W-B7A04 Manual And Instructions
CJ1W-B7A04 datasheetPDF datasheet
CJ1W-B7A04 HardwareOPERATION MANUAL

OMRON CJ1W-B7A04 Product information and technical parameters:
Brand: OMRON
Name: B7A Interface Unit
Model: CJ1W-B7A04
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.

Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0 CJ1W-B7A04. 2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block CJ1W-B7A04
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals CJ1W-B7A04. Unit classification: CJ1 CPU Bus Unit.
Product name: EtherNet/IP Unit.
Specifications:Communications cable,
Shielded twisted-pair STP),
cable Categories: 100 Ω at 5,5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max.
No. of unit numbers allocated: 1.
Current consumption: 5V system, 0 CJ1W-B7A04. 41A;
24V system, --.
Standards: UC1, N, L, CE.
Introducing the New EtherNet/IP Unit.
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet.
Managed by the ODVA (Open DeviceNet Vendors,
Association), it has open standards and is,
used with a wide range of industrial devices.
The EtherNet/IP Unit supports tag data links,
to enable sharing data between devices at,
Ethernet nodes and a message service for,
sending and receiving data when required.
The EtherNet/IP Unit supports the same,
FINS/UDP and FINS/TCP functionality,
as Ethernet Units.
Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocateed: 1 CJ1W-B7A04.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-B7A04.
All inputs are isolated.