Unit type: CJ1 CPU Bus Units.
Unit with MECHATROLINK-II interface.
synchronous communications.
Direct operation by ladder programming.
No. of axes: 16 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
and Batch Management.
Control Unit that supports MECHATROLINK-II.
of the MECHATROLINK Members Association.
Product name: CJ-series I/O Control Unit.
Specifications: Mount one I/O Control Unit,
on the CPU Rack when connecting one or,
more Expansion Racks.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Connected Unit:
CJ1W-II101 I/O Interface Unit,
Mount to the right of the CPU Unit.
Current consumption: 5V , 0 CJ1W-NCF71-MA. 02A;
24V, --.
Standards: UC1, N, L, CE.
Expand CJ/NJ-series with These Units
CJ1W-NCF71-MA
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block CJ1W-NCF71-MA.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications CJ1W-NCF71-MA.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 24VDC, 7mA,
12 to 24 VDC, 0.5 A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1 CJ1W-NCF71-MA.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-NCF71-MA.
All inputs are isolated.