Name: CS1D CPU Backplane.
2 Units max. (for duplex operation);
Number of I/O Units, 5 Units max.
(including the I/O Control Units).
26V system, --.
Standards: UC1, CE.
Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,CPU Backplane;
Connecting Cable,
Long-distance Connecting Cable.
Current consumption: 5V system, 0 CS1D-BC042D. 92A;
26V system, --.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
CS1D-BC042D Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0.02 μs;
Duplex CPUs, --;
Interrupt functions, OK CS1D-BC042D.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Connector: 100Base-TX.
Communications service: FINS communications service (TCP/IP, UDP/IP),
FTP server functions, socket services, mail transmission service,
mail receive (remote command receive),
automatically adjusted PLC built-in clock,
server/host name specification CS1D-BC042D. Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Single CPU System only;
Number of Power Supply Units, 2 Units max.
(for duplex operation);
Number of I/O Units, 8 slots max.
Current consumption: 5V system, 0.17A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1D-BC042D.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-BC042D.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.