OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC CPU unit >> CS1D CPU and other CS1D units >> CS1D-BI092 Programmable Controllers

CS1D-BI092 Programmable Controllers

OMRON CS1D-BI092 Manual And Instructions
CS1D-BI092 datasheetPDF datasheet

OMRON CS1D-BI092 Product information and technical parameters:
Brand: OMRON
Name: Programmable Controllers
Model: CS1D-BI092
Name: CS1D Expansion Backplane.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Number of Power Supply Units, 2 Units max.
(for duplex operation);
Number of I/O Units, 9 Units max.
Current consumption: 5V system, 0.28A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.

I/O bits: 960 (Expan-sion Racks: 2).
Program capacity: 10K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 bank)Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 16 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max CS1D-BI092 CS1D-BI092
(Settable to 1 ms/point).
Externa connection, MIL connector.
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data CS1D-BI092.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block CS1D-BI092.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1D-BI092.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-BI092.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>