Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, MIL connector.
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
analog input signals into binary data.
binary data into analog output signals.
Specifications: Optical cable(H-PCF cable).Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications:24 VDC, 0.5 A,
32 outputs; Sourcing.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CS1W-AD161.
Words required: 2 words
CS1W-AD161
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Control method: Semiclosed loop with automatic trapezoid or S-curve acceleration/deceleration.
Control output signals: Analog CS1W-AD161.
Controlled axes: 2 axes max.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1 CS1W-AD161.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-AD161.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-AD161.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.