Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
0.3A 64 outputs; Sinking.
C200HX/HG/HE Expansion I/O Rack, No.
SYSMAC BUS Slave Rack, No.
Words required: 4 words.
26 V system, --.
Standards: UC1, N, L, CE.
Highly Reliable Process Control.
Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 250 VAC or 120 VDC,
2 A max. Independent contacts, 8 outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CS1W-OD261.
Words required: 1 word.
Current consumption: 5V system, 0
CS1W-OD26110A;
26 V system, 0.006per simultaneously ON outputs.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords,
(DM: 32 Kwords, EM: 32 Kwords×3banks);
LD execution time, 0 CS1W-OD261. 02 μs;
Duplex CPUs, OK;
Interrupt functions, --.
Current consumption: 5 V system, 0.82A;
26 V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Product name: CS1 CPU Backplane CS1W-OD261.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 5 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CS1W-OD261.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Anaalog Input Units for converting,
analog input signals into binary data CS1W-OD261.
Analog Output Units for converting ,
binary data into analog output signals.