OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PDC11 Process Analog I/O Units

CS1W-PDC11 Process Analog I/O Units

OMRON CS1W-PDC11 Manual And Instructions
CS1W-PDC11 datasheetPDF datasheet
CS1W-PDC11 OPERATION Manual

OMRON CS1W-PDC11 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PDC11
Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Unit type: CS1 Basic I/O Units.
Product name: Safety Relay Unit.
Specifications: Function, Emergency stop Unit;
Power supply voltage, 24 VDC;
Number of input words,
1 word or 2 words (Shared inputs);
Contact type (Safety output), DPSTNO;
Number of general inputs, 4 inputs/common;
Externa connections, Remov able terminal block CS1W-PDC11.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No CS1W-PDC11
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.10A;
26 V system, --.
Standards: U, C, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CS1W-PDC11. Unit type: CS1 CPU Bus Units.
Product Name: MECHATROLINK-II,
compatible Position Control Unit.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder,
programming, Control mode:
Position control, speed control,
or torque control; No. of axes: 2.
No. of unit numbers allocated: 1 CS1W-PDC11.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes,
in a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Name: CS1D Duplex Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Not supported.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring H-PCF cable;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and aat high speed CS1W-PDC11.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systeems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable CS1W-PDC11.


...More relevant models >>>>