OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PTS56 Process Analog I/O Units

CS1W-PTS56 Process Analog I/O Units

OMRON CS1W-PTS56 Manual And Instructions
CS1W-PTS56 datasheetPDF datasheet
CS1W-PTS56 User's Manual

OMRON CS1W-PTS56 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PTS56
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CS1W-PTS56.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.20A; 26V, 0 CS1W-PTS5620A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface,Open-loop control by,
pulse train output/Line-driver output;
Number of control axes, 1 axis CS1W-PTS56.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE.
High-speed, High-precision,
positioning with 1, 2, or 4 axes.
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines CS1W-PTS56.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-PTS56.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-PTS56.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>