OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PTS55 Process Analog I/O Units

CS1W-PTS55 Process Analog I/O Units

OMRON CS1W-PTS55 Manual And Instructions
CS1W-PTS55 datasheetPDF datasheet
CS1W-PTS55 User's Manual

OMRON CS1W-PTS55 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PTS55
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface, Open-loop control by,
pulse train output/Open-collector output;
Number of control axes, 2 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE CS1W-PTS55.
High-speed, High-precision,
positioning with 1, 2, or 4 axes CS1W-PTS55
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps CS1W-PTS55.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units) CS1W-PTS55.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-PTS55.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-PTS55.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>