Specifications: Input, NPN (+ common), 8 points.
I/O connections: Sensor I/O connector.
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
preventative maintenance and troubleshooting capabilities.
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
Detects ground faults or disconnects and notifies the Master.
Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction DRT2-ID08C.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
DRT2-ID08C
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs, NPN(+ common), 32 inputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector DRT2-ID08C.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. classification: Power MOS FET relay output.
I/O points: 16 points.
Rated voltage: 24 VDC DRT2-ID08C.
Relay coil rating: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available. Unit: Terminal block model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: M3 terminal board.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Name: Expansion Units.
Specifications: Outputs;
8 outputs; PNP;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiaal cost can be reduced DRT2-ID08C.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee DRT2-ID08C.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.