Specifications: Inputs, PNP (- common), 32 inputs.
I/O connections: MIL connector.
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws.
Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system DRT2-ID32B-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
DRT2-ID32B-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common) DRT2-ID32B-1.
I/O points: 16.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment DRT2-ID32B-1.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Input 8 points corresponding to NPN (+ public)
Remote I/O terminal (transistor connector type 4 point /8 point)
Achieve business card in half the size of the connector input type
Can switch between long range / high speed communication mode.
A product with 4 points and 8 points.
Save space.
Small size of X H45mm W58mm.
Through the cable leads to the direction of the reunification of the above, can reduce the occupied area.
With input short circuit protection function.Name: CompoNet Gateway Unit for CC-Link.
Specifications: CC-Link Communications,
Specification, Station Type,
Remote device stations;
Number of stations occupied: 4.
CC-Link Version: Version 1.10 or 2.00.
(Selected using mode switch.);
CompoNet Communications Specification,
communications Types of,
Remote I/O Communications;
Maximum I/O capacit, Word Slave Units:
2,048 I/O points total(1,024 inputs and,
1,024 outputs)Bit Slave Units:
512 I/O points total.
(256 inputs and 256 outputs)
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced DRT2-ID32B-1.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee DRT2-ID32B-1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.