OMRON
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-MD16TA-1 Transistor Remote I/O Terminals with 3-tier Terminal Blocks

DRT2-MD16TA-1 Transistor Remote I/O Terminals with 3-tier Terminal Blocks

OMRON DRT2-MD16TA-1 Manual And Instructions
DRT2-MD16TA-1 datasheetPDF datasheet
DRT2-MD16TA-1 PROGRAMMING MANUAL
DRT2-MD16TA-1 INSTRUCTION Manual

OMRON DRT2-MD16TA-1 Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals with 3-tier Terminal Blocks
Model: DRT2-MD16TA-1
Specifications: I/O; PNP (input: - common,
output: + common)); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.

Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common DRT2-MD16TA-1.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation DRT2-MD16TA-1
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No DRT2-MD16TA-1.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing DRT2-MD16TA-1.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Specifications: Outputs, NPN((- common), 32 outputs DRT2-MD16TA-1.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easiily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring DRT2-MD16TA-1.
User boards attach easily to the DRT2-@D32BV(-1) using screws.


...More relevant models >>>>