Specifications: I/O, NPN (input: + common, output: - common), 16 inputs/16 outputs.
I/O connections: MIL connector.
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws.
Specifications: Outputs; NPN (- common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals DRT2-MD32BV.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations
DRT2-MD32BV
No relay terminal block terminals required.
Detachable cassette-type circuit sections. I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection) DRT2-MD32BV.
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
I/O classification: Output.
Internal I/O circuit common: NPN (- common) DRT2-MD32BV.
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Name: CompoNet Communication Unit.
Specifications: Up to 64 Slice I/O,
Units can be connected.
(Inputs: 32 bytes maximum,
Output: 32 bytes maximum).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiall cost can be reduced DRT2-MD32BV.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee DRT2-MD32BV.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.