Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P E52-CA20AY D=8 NETU 1M
E52-CA20AY D=8 NETU 1M
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E52-CA20AY D=8 NETU 1M. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E52-CA20AY D=8 NETU 1M.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adappter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E52-CA20AY D=8 NETU 1M.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E52-CA20AY D=8 NETU 1M.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).