Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
monitor load current.
Total run time monitoring.
and constant-current control.
variable load resistance.
UL, and IEC/EN (TÜV) certified.
Name: Short-circuit Unit.
Current flow: 30 A, 40 A.
Applicable SSR: G3PA-430B-VD, G3PA-240B-VD.
Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation. Type: Standard.
Contact form: DPDT G3PW-A220EC-S-FLK.
Open structure: Solder terminals.
Stable Contact Reliability and Long Life
G3PW-A220EC-S-FLK
Easy to mount, wire, and use.
A large selection of models including various contact forms,
DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life,
(under rated load): 500,000 operations.
Models also available with built-in diodes and for use as,
auxiliary power relays G3PW-A220EC-S-FLK. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 60 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2 G3PW-A220EC-S-FLK. )
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Contact form: SPST-NO.
Type: Models with Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load)) G3PW-A220EC-S-FLK.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0 G3PW-A220EC-S-FLK. 5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).