OMRON G3ZA-4H203-FLK-UTU Manual And Instructions
G3ZA-4H203-FLK-UTU datasheetPDF datasheet
G3ZA-4H203-FLK-UTU REFERENCE MANUAL

OMRON G3ZA-4H203-FLK-UTU Product information and technical parameters:
Brand: OMRON
Name: Multi-channel Power Controller
Model: G3ZA-4H203-FLK-UTU
Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.

Isolation: Photocoupler.
Zero cross function: --.
Indicator: NO.
Rated output load: 3 A at 4 to 48 VDC *2 .
Rated input voltage: 4 to 24 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) G3ZA-4H203-FLK-UTU.
Socket type, same size as LY Power Relays G3ZA-4H203-FLK-UTU
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection) G3ZA-4H203-FLK-UTU.
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures G3ZA-4H203-FLK-UTU.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5V G3ZA-4H203-FLK-UTU.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (ttype -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type) G3ZA-4H203-FLK-UTU.
A model with an action indicator to check the status of the input. (type N)