OMRON
Home >> Products >> OMRON >> Security products >> Safety controller >> G9SX-EX041-T-RC Flexible Safety Unit

G9SX-EX041-T-RC Flexible Safety Unit

OMRON G9SX-EX041-T-RC Manual And Instructions
G9SX-EX041-T-RC datasheetPDF datasheet
G9SX-EX041-T-RC USER'S MANUAL

OMRON G9SX-EX041-T-RC Product information and technical parameters:
Brand: OMRON
Name: Flexible Safety Unit
Model: G9SX-EX041-T-RC
Safety outputs: Instantaneous, --; OFF-delayed, 4 PST-NO.
Auxiliary outputs *1: 1(Semiconductor).
OFF-delay time: *2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs.

Type of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) G9SX-EX041-T-RC.
Forced open action structure G9SX-EX041-T-RC
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Number of beams: 14.
Protective height: 305mm.
Model: PNP output.
EASY type reduces implementation costs.
with 1/2 the mounting time.
In pursuit of simple functions: Upon detection of personnel,
the machine stops G9SX-EX041-T-RC.
Can be used for simple hand intrusion detection.
Implementation costs can be significantly reduced. Number of beams: 56.
Protective height: 1680mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A G9SX-EX041-T-RC.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact fforms G9SX-EX041-T-RC.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads G9SX-EX041-T-RC.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.