OMRON
Home >> Products >> OMRON >> Security products >> Safety controller >> G9SX-GS226-T15-RT Safety Guard Switching Unit

G9SX-GS226-T15-RT Safety Guard Switching Unit

OMRON G9SX-GS226-T15-RT Manual And Instructions
G9SX-GS226-T15-RT datasheetPDF datasheet
G9SX-GS226-T15-RT USER'S MANUAL
G9SX-GS226-T15-RT user's manual

OMRON G9SX-GS226-T15-RT Product information and technical parameters:
Brand: OMRON
Name: Safety Guard Switching Unit
Model: G9SX-GS226-T15-RT
Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4).

Number of beams: 14.
Protective height: 280mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A G9SX-GS226-T15-RT.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module G9SX-GS226-T15-RT
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Actuator: Roller lever (resin lever, metal roller).
Conduit size: 1-conduit; M20 G9SX-GS226-T15-RT.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability G9SX-GS226-T15-RT.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 16.
Protective height: 320mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Number of beams: 70.
Protective height: 1400mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
SSeries connection is possible only with the MSF4800A G9SX-GS226-T15-RT.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt Curtain functions G9SX-GS226-T15-RT.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.


...More relevant models >>>>