Action determine the color, can switch the green / Red 2 kinds of color display.
Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-HTA-L1AT11 AC100-240.
Digital rotating pulse meter with high speed measurement for 50kHz
K3HB-HTA-L1AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, the highest speed up to 50kHzType: no instantaneous contact.
Terminal configuration type: special terminal configuration.
Pin type: 8 pin K3HB-HTA-L1AT11 AC100-240.
Action mode / reset mode: time limit action / auto reset.
Output mode: contact output.
Installation method: embedded installation / front mounting.
1 units can be in 0.5 seconds to 120 seconds, select the 4 time range.
Achieved UL, CSA, NK, LR certification, in compliance with EN61812-1.
Conform to the CE mark, CCC. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type K3HB-HTA-L1AT11 AC100-240.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied toOperating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switchh) K3HB-HTA-L1AT11 AC100-240.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rrewiring K3HB-HTA-L1AT11 AC100-240.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.