Action determine the color, can switch the green / Red 2 kinds of color display.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Installation method: surface mount.
Action function: 8 multi-function action (A, B, C, D, E, F, G, H,).
Action mode / reset mode: time limit action / auto reset / external reset.
Set lock mechanism.
External connection: terminal with screw.
Time limit contact: 1c.
Instantaneous contact: No.
1 timer to achieve AC/DC free power,
8 action functions 0 K3HB-RNB-CPAC11 AC100-240. 1 seconds to 9990 hours
K3HB-RNB-CPAC11 AC100-240
Through time display windows wide, eye-catching.
Free power mode using AC24 ~ 240V/DC12 ~ 240V.
And the DC specification does not have to specify the polarity.
8 action functions can be selected by the action function switch.
Combined operation of time setting switch and time unit switch,
RealizationType of input: AC current input K3HB-RNB-CPAC11 AC100-240.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-RNB-CPAC11 AC100-240.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNetOutput: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 111-pin models and five modes for 8-pin models K3HB-RNB-CPAC11 AC100-240.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available K3HB-RNB-CPAC11 AC100-240.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.