OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VM-03015D Switching Mode Power Supply

S8VM-03015D Switching Mode Power Supply

OMRON S8VM-03015D Manual And Instructions
S8VM-03015D Connection Guide

OMRON S8VM-03015D Product information and technical parameters:
Brand: OMRON
Name: Switching Mode Power Supply
Model: S8VM-03015D
Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 30W.
Output voltage: 15V.
Output current: 2A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)

Control power supply voltage: 24 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) S8VM-03015D.
Detect three-phase AC current for under and/or overcur,
rent using current converter S8VM-03015D
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) S8VM-03015D.
LED operation indicator.
UL/CSA approval (SDV-F@). Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage S8VM-03015D.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45).
Cable length: 0.3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks S8VM-03015D. Model: PF (front-mounting), page 22.
Approx: 34 g.
Number of pins: 8 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Modelss,
Models available with finger protection S8VM-03015D.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available.


...More relevant models >>>>