OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VM-10005D Switching Mode Power Supply

S8VM-10005D Switching Mode Power Supply

OMRON S8VM-10005D Manual And Instructions
S8VM-10005D Connection Guide

OMRON S8VM-10005D Product information and technical parameters:
Brand: OMRON
Name: Switching Mode Power Supply
Model: S8VM-10005D
Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 5V.
Output current: 20A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)

Item: Logic Alarm Cable (2 m).
Easy-to-use and Compact 10-Channel Logger,
with Internal 4 GB Flash Memory. Type: single socket connector for PCB substrate.
Contact number: 5.
Wiring simple and e-CON * specifications for connectors;
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted S8VM-10005D.
Wiring is simple, no special tools required,
Can be re wiring (maintenance) S8VM-10005D
Acceptable range for each connector
Stranded AWG28 (0.08mm2) ~ AWG20 (0.5mm2),
Any core wire size between.
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided.
UL standard (Document No. E103202) identified as a standard product S8VM-10005D.
Cable connector with the UL standard certification of products.
"Cable specifications: Fire-retardant, Robot cable.
Cable length L: 5 m.
Cable outer diameter: 6 mm.
Straight (Socket)/angled (Plug).
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors S8VM-10005D.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF contrrol, phase control, and cyclic control S8VM-10005D.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads S8VM-10005D.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).


...More relevant models >>>>