OMRON SRM1-C02-V2 Manual And Instructions
SRM1-C02-V2 SYSTEM MANUAL
SRM1-C02-V2 OPERATION MANUAL
SRM1-C02-V2 OPERATION MANUAL

OMRON SRM1-C02-V2 Product information and technical parameters:
Brand: OMRON
Name: Master control unit
Model: SRM1-C02-V2
Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.

Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is the,
Same Shape as 16-point Remote I/O Terminals.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D). Name: Screw Terminal Block with Relay Outputs SRM1-C02-V2.
Specifications: Outputs;
8 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet SRM1-C02-V2
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site SRM1-C02-V2.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Short/disconnection detection: Supported.
Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector SRM1-C02-V2.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Name: Expansion Units.
Specifications: inputs ;
16 inputs; PNP;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiall cost can be reduced SRM1-C02-V2.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee SRM1-C02-V2.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.