K3HB-HTA-L2AT11 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-HTA-L2AT11 AC100-240
Name: Temperature panel
Sort: PDF datasheet
File language: English
File size: 1.35MB
Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model K3HB-HTA-L2AT11 AC100-240 PDF datasheet K3HB-HTA-L2AT11 AC100-240 )
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function K3HB-HTA-L2AT11 AC100-240 PDF datasheet.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-HTA-L2AT11 AC100-240 PDF datasheet.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating puulse meter with high speed measurement for 50kHz K3HB-HTA-L2AT11 AC100-240 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFFF pulse signals, the most up to 50kHz of high-speed pulse measurement K3HB-HTA-L2AT11 AC100-240 PDF catalog.
Rotation measurement of high speed rotating objects can be carried out.
Support
Related products
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Load sensor, mV instrument
K3HB-VLC-L1BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-CPAC11 AC100-240
OMRON Time interval table K3HB-PPB-CPAC11 AC100-240
Input type: PNP input type. Event input term