I/O Terminal Cover For 38-pin block, special type 3G2A5-COV11Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector NPN outputs (pulses) CS1D-CPU65H OPERATION MANUAL.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0
CS1D-CPU65H25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Name: Three-tier Screw Terminal Block CS1D-CPU65H OPERATION MANUAL.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1D-CPU65H OPERATION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Output method: Transistor sinking.
Inputs: ---.
Outputs: 32.Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords,
(DM: 32 Kwords, EM: 32 Kwords×3banks);
LD execution time, 0.02 μs;
Duplex CPUs, OK;
Interrupt functions, --.
Current consumption: 5 V system, 0.82A;
26 V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Ranges : -10 to + 10V, 0 to 10V, 0 to 5V, or 0 to 20mA.
Power supply : Built-in, DC/DC converter.Name: e-CON Connector Type.
Specifications: Analog inputs;
4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CS1D-CPU65H Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1D-CPU65H Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.