OMRON
Home >> Download >> OMRON >> Manual Download >> EJ1G-HFUB-NFL2 OPERATION MANUAL ()

EJ1G-HFUB-NFL2 OPERATION MANUAL ()

Brand: OMRON
Product model: EJ1G-HFUB-NFL2
Name: Temperature Controller
Sort: OPERATION MANUAL
File language: English
File size: 4.73MB
Sensing method: Retroreflective type.
Sensing distance: 200 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Photomicrosensor with light,
modulation for reduced external light,
interference.
Easy adjustment and optical axis monitoring with a light indicator.
Wide operating voltage range: 5 to 24 VDC EJ1G-HFUB-NFL2 OPERATION MANUAL.
Supports connection with Programmable Controllers (PLCs) EJ1G-HFUB-NFL2
Easy-to-wire connectors assure easy maintenance. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485 EJ1G-HFUB-NFL2 OPERATION MANUAL.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0 EJ1G-HFUB-NFL2 OPERATION MANUAL. 2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. E32-A04 type: special beam type; wafer mapping,
Specialty: ultra thin type (t=2mm); opening angle 3 degree adjustment optical axis after the factory,
Bending radius (mm): R10.
Fiber element for meeting diversified needsSize: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mannual, RUN/STOP, alarm), interactive display PV/SV EJ1G-HFUB-NFL2 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation EJ1G-HFUB-NFL2 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.