I/O classification: Digital input.
Internal I/O circuit common: PNP (– common).
I/O points: 16.
I/O connection method: M3 terminal block.
Added to the Remote I/O Terminal Series.
I/O Points, or Output Points.
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.
EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range.
Maximum input pulse frequency of 4MHz,
(Line driver input after quadrature).
High-speed network EtherCAT enables,
high-speed and accurate control SRT2-ID16T-1.
Selectable two input types:
Open collector input and line driver input.
Built-in two external latch inputs,
and one reset input
SRT2-ID16T-1
Selectable node address settings: setting with,
rotary switches and setting on tool software.
Detachable screw terminal will facilitate,
the maintenance work. Internal I/O common: NPN.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max SRT2-ID16T-1.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors SRT2-ID16T-1.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Name: CompoNet Gateway Unit for CC-Link.
Specifications: CC-Link Communications,
Specification, Station Type,
Remote device stations;
Number of stations occupied: 4.
CC-Link Version: Version 1.10 or 2.00.
(Selected using mode switch.);
CompoNet Communications Specification,
communications Types of,
Remote I/O Communications;
Maximum I/O capacit, Word Slave Units:
2,048 I/O points total(1,024 inputs and,
1,024 outputs)Bit Slave Units:
512 I/O points total.
(256 inputs and 256 outputs)
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced SRT2-ID16T-1.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee SRT2-ID16T-1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.