OMRON
Home >> Products >> OMRON >> Master slave station products >> CompoBus/S >> SRT2-OD04-1 Transistor Remote I/O Terminals

SRT2-OD04-1 Transistor Remote I/O Terminals

OMRON SRT2-OD04-1 Manual And Instructions
SRT2-OD04-1 datasheetPDF datasheet
SRT2-OD04-1 SETUP MANUAL

OMRON SRT2-OD04-1 Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: SRT2-OD04-1
I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.

Name: Expansion Units.
Specifications: Outputs;
8 outputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet SRT2-OD04-1.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-OD04-1
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error SRT2-OD04-1. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires SRT2-OD04-1.
DIN track mounting. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiiple contacts SRT2-OD04-1.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,

switch and with tool software SRT2-OD04-1.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.