OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-PPB-FLK1AT11 AC100-240 PDF datasheet (datasheet)

K3HB-PPB-FLK1AT11 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-PPB-FLK1AT11 AC100-240
Name: Time interval table
Sort: PDF datasheet
File language: English
File size: 1.59MB
Input type: DC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-PPB-FLK1AT11 AC100-240 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-FLK1AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevDetect abnormal voltages applies to equipment to,
protect against equipment failure K3HB-PPB-FLK1AT11 AC100-240 PDF datasheet.
Use in either overvoltage or undervoltage mode.
Monitor AC or DC currents with one Relay.
Settings for the operating value, hysteresis, and operating time.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires K3HB-PPB-FLK1AT11 AC100-240 PDF datasheet.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of ooperation K3HB-PPB-FLK1AT11 AC100-240 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-FLK1AT11 AC100-240 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products