Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
and Different Applications.
control for external devices.
CJ1W-OD234 can help to increase system.
throughput.
Name: Loop-control CPU Unit.
I/O bits: 1,280 bits.
Program capacity: 60K steps.
DM words: 32K words.
EM words: 32K words × 3 banks E0_00000 to E2_32767.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs) CJ1W-OD201.
Input points: 4 inputs
CJ1W-OD201
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0 CJ1W-OD201. 3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE CJ1W-OD201.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. I/O capacity/Mountable Units(Expansion Racks): 1, 280 points/40 Units (3 Expansion Racks max.).
CJ1G-CPU44H Program capacity: 30K steps.
CPU Unit CJ1G-CPU44H Data memory capacity: 64K words(DM: 32K words, EM: 32K words × 1 bank).Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 16 inputs(High speed);
Input voltage and current: 24 VDC, 7 mA;
Commons, 16 points, 1 common; External connection,
Removable terminal block; No. of words allocated, 1 word.
Currrent consumption: 5V, 0 CJ1W-OD201. 13A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memoory in the CPU Unit CJ1W-OD201.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.