OMRON
Home >> Products >> OMRON >> Master slave station products >> EtherCAT remote I/O terminal >> GX-MD1621 EtherCAT Remote I/O Terminals

GX-MD1621 EtherCAT Remote I/O Terminals

OMRON GX-MD1621 Manual And Instructions
GX-MD1621 datasheetPDF datasheet
GX-MD1621 PROGRAMMING MANUAL
GX-MD1621 INSTRUCTION MANUAL
GX-MD1621 Safety Precautions

OMRON GX-MD1621 Product information and technical parameters:
Brand: OMRON
Name: EtherCAT Remote I/O Terminals
Model: GX-MD1621
Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.

Name: Expansion Units.
Specifications: Outputs;
8 outputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet GX-MD1621.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system GX-MD1621
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error GX-MD1621. Specifications: Inputs; NPN (+ common); 16 inputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from the communications connector.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensors with Pre-wired Cables without Using,
Special Tools GX-MD1621.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection. EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range.
Maximum input pulse frequency of 4MHz,
(Line driver inpuut after quadrature) GX-MD1621.
High-speed network EtherCAT enables,
high-speed and accurate control.
Selectable two input types:
Open collector input and line driver input.
Built-in two external latch inputs,
and one reset input.
Selectable node address settings: setting with,
rotary switches and setting on tool software GX-MD1621.
Detachable screw terminal will facilitate,
the maintenance work.


...More relevant models >>>>