OMRON
Home >> Products >> OMRON >> Master slave station products >> EtherCAT remote I/O terminal >> GX-OD1622 Digital I/O Terminal 3-tier Terminal Block Type

GX-OD1622 Digital I/O Terminal 3-tier Terminal Block Type

OMRON GX-OD1622 Manual And Instructions
GX-OD1622 datasheetPDF datasheet
GX-OD1622 PROGRAMMING MANUAL
GX-OD1622 INSTRUCTION MANUAL
GX-OD1622 Safety Precautions
GX-OD1622 Safety Precautions

OMRON GX-OD1622 Product information and technical parameters:
Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD1622
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.

Input/Output: Outputs.
Internal I/O circuit common: NPN (– common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation GX-OD1622. No tools are required for,
connection to a variety of devices GX-OD1622
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time GX-OD1622.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration. Specifications: Inputs, NPN(+ common), 32 inputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector GX-OD1622.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. Short/disconnection detection: Not supported.
Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connectiions: Molex connector GX-OD1622.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The ciircuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires GX-OD1622.
DIN track mounting.


...More relevant models >>>>