OMRON
Home >> Products >> OMRON >> Master slave station products >> EtherCAT remote I/O terminal >> GX-OD1612 Digital I/O Terminal 3-tier Terminal Block Type

GX-OD1612 Digital I/O Terminal 3-tier Terminal Block Type

OMRON GX-OD1612 Manual And Instructions
GX-OD1612 datasheetPDF datasheet
GX-OD1612 PROGRAMMING MANUAL
GX-OD1612 INSTRUCTION MANUAL
GX-OD1612 Safety Precautions
GX-OD1612 Safety Precautions

OMRON GX-OD1612 Product information and technical parameters:
Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD1612
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.

Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications GX-OD1612.
Detachable screw terminal block facilitates,
the maintenance GX-OD1612
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software GX-OD1612.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced GX-OD1612.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: System Units; Turnback Units.
Specifications: Left Turnback Unit,
(Mounts to the left side of Slice I/O,
Terminal. Can supply power to I/O Units.)
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiial cost can be reduced GX-OD1612.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee GX-OD1612.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>